Jan 01, 2020 · Robotic lead placement exhibits a good clinical response post-operatively “Statistically significant improvements in left ventricular ejection fraction, NYHA heart failure class” Kamath et al. Prospective cohort: N = 78 undergoing robotic epicardial lead placement: Pacing threshold, lead impedance short- and long-term (>12 months).
Implantation of a cardiac resynchronization therapy and ...
Long-term outcome robotic epicardial lv lead placement of leads and patients follo wing robotic epicardial left ventricular lead placement for cardiac resynchronization therapy. Pacing Clin Electrophysiol 2011;34:235–240. 9. Burger H, Kempfert J, van Linden A, Szalay Z, Schoenburg M, Walther T, Ziegelhoeffer T. Endurance and performance of two different concepts for left
A Surgical Case for Cardiac Resynchronization Therapy
outcomes after CRT. The use of robotic epicardial lead insertion has been of significant benefit in combining preoperative determination of placement site with safe LV lead placement. As we move forward with this technology, we can continue to expect further benefits of precise placement of LV leads in cardiac resynchronization therapy.
To provide a minimally invasive option for these patients with LV lead failures, we developed a technique of endoscopic, epicardial LV lead implantation with the use of the da Vinci robotic system. The surgical approach targets the posterolateral wall through a novel posterior approach. KW - 24
Doll and associates [1] recently described epicardial left ventricular (LV) lead placement with the Medtronic 5071 Epicardial pacing lead (Medtronic, Inc, Minneapolis, MN) through an anterolateral mini-thoracotomy facilitated by using the Medtronic 10626 lead implant tool for cardiac resynchronization robotic epicardial lv lead placement therapy in 7 patients with transvenous implantation failure. However, we have some additional ... kate spade new york flower purseforum
Midterm Follow-up of Robotic Biventricular Pacing ...
METHODS: : Forty-two patients underwent implantation of LV epicardial leads using robotic assistance and the posterior approach. Half of the patients had prior cardiac surgery. All leads were placed robotic epicardial lv lead placement in an optimal site along the posterolateral surface of the LV.
Epicardial Left Ventricular Lead Placement for Cardiac ...
Fourteen patients (11%) required epicardial LV lead placement via left thoracotomy or thoracoscopy with mean intensive care unit stay of 2.1 days and inotrope use in 38%. Complications included ventricular fibrillatory arrest, stroke, hypotension, and major bleeding, but there was no difference in 90‐day survival between epicardial and ...
Horizon Scanning Technology Prioritising Summary ...
assisted approach for epicardial left ventricular (LV) lead placement and may offer an alternative to LV lead placement by means of a limited thoracotomy. Operations are performed under general anae sthetic with selective right lung ventilation. Robotic technology allows placement of the lead onto the posterobasal wall of the LV surface ...
A Shifting Paradigm in Robotic Heart Surgery: From Single ...
Fig. 3 Port placement for robotic TECAB, and all robotic off-pump left chest procedures: LAA ligation, pericardiectomy, LV lead placement, and VT ablation (note 2 sources of CO 2 insufflation). CO 2 , carbon dioxide; LAA, left atrial appendage; LV, left ventricular; TECAB, totally endoscopic coronary artery bypass; VT, ventricular tachycardia.